Partener Siemens
Sisteme Alarma Supraveghere Video Control Acces

Control Acces Siemens

Module Usa Siemens Sipass Integrated

Model: ADS5200 - Single reader interface module including base plate

• The ADS5200 provides a Clock&Data/Wiegand interface between a card reader and the advanced central controller (AC5102 or AC5200) for one card reader. When a cardholder presents an access card at an entry or exit reader the ADS5200 reader interface interprets the encoded information and sends this data to the controller. The controller then checks the validity of the cardholder, and if the appropriate permissions have been assigned� the controller sends a message back to the reader interface allowing it to unlock the door and provide passage. It can also report the status of the door (locked or unlocked) at any time.

• Note: The ADS5200 does not have an RS485 interface for card readers. It supports Clock&Data or Wiegand readers only.

Date Tehnice

Interfaces: FLN connection to controller: RS485 To readers: Clock&Data or Wiegand port

Operating voltage: 12 VDC ±20 %

Power consumption: 12 W

Inputs: 1 x REX-button / 1 x Door contact / 2 x Auxiliary / All inputs unsupervised or supervised

Outputs: 1 x Lock output relay (30 VDC, 2 A) / 1x Open-collector output (100 mA, 12 VDC)

Tamper switch: Optional, auxiliary input

Firmware: Flash upgradeable

Indicators: Power, Activity, Communication

Dimensions (W x H x D): 125 x 125 x 34 mm

Weight: 0.25 kg

Approval: CE, UL294, C-Tick


Model: ADS5210 - Single reader interface module including base plate and plastic housing
modul usa siemens sipass integrated

Data sheet
descarca .pdf

• The ADS5210 provides a Clock&Data/Wiegand interface between a card reader and the advanced central controller (AC5100, AC5102 or AC5200) for one card reader. When a cardholder presents the access card at an entry or exit reader the ADS5210 reader interface interprets the encoded information and sends this data to the controller. The controller then checks the validity of the cardholder, and if the appropriate permissions have been assigned, the controller sends a message back to the reader interface allowing it to unlock the door and provide passage. It can also report the status of the door (locked or unlocked) at any time.

• Note: The ADS5210 does not have an RS485 interface for card readers. It supports Clock&Data or Wiegand readers only.

Date Tehnice

Interfaces: FLN connection to controller: RS485 To readers: Clock&Data or Wiegand port

Operating voltage: 12 VDC ±20 %

Power consumption: 12 W

Outputs: 1 x Lock output relay (30 VDC, 2 A) / 1x Open-collector output (100 mA, 12 VDC)

Inputs: 1 x REX-button / 1 x Door contact / 2 x Auxiliary / All inputs unsupervised or supervised

Tamper switch: Optional, auxiliary input

Firmware: Flash upgradeable

Indicators: Power, Activity, Communication

Dimensions (W x H x D): 150 x 150 x 76 mm

Housing protection: IP55

Housing: ABS plastic

Weight: 0.55 kg

Approval: CE


Model: ADD5100 - Dual reader interface including base plate
modul usa siemens sipass integrated

Data sheet
descarca .pdf

• The ADD5100 provides an interface between a card reader and the advanced central controller (AC5102 or AC5200) for up to two card readers. When a cardholder presents an access card at an entry or exit reader the ADD5100 reader interface interprets the encoded information and sends this data to the controller. The controller then checks the validity of the cardholder, and if the appropriate permissions have been assigned, the controller sends a message back to the reader interface allowing it to unlock the door and provide passage. It can also report the status of the door (locked or unlocked) at any time.

Date Tehnice

Interfaces: FLN connection to controller: RS485 To readers: One RS485 bus for up to two RS485 readers CerPass protocol) OR two Wiegand/Clock&Data ports

Operating voltage: 24 VDC ±20 %

Power output: Reader: 300 mA / Ancillary: 1 A

Power consumption: 25 W

Outputs: 1 x Lock output relay (30 VDC, 2 A) / 1 x Auxiliary relay (30 VDC, 2 A)

Inputs: 1 x REX-button / 1 x Door contact / 3 x Auxiliary / All inputs unsupervised or supervised

Tamper switch: Optional, auxiliary input

Firmware: Flash upgradeable

Indicators: Power, Activity, Communication

Dimensions (W x H x D): 125 x 125 x 34 mm

Weight: 0.3 kg

Approval: CE, UL294, C-Tick


Model: ADD5110 - Dual reader interface including base plate and plastic housing
modul usa siemens sipass integrated

modul usa siemens sipass integrated

Data sheet
descarca .pdf

• The ADD5110 provides an interface between a card reader and the advanced central controller (AC5102 or AC5200) for up to two card readers. When a cardholder presents the access card at an entry or exit reader the ADD5110 reader interface interprets the encoded information and sends this data to the controller. The controller then checks the validity of the cardholder� and if the appropriate permissions have been assigned� the controller sends a message back to the reader interface allowing it to unlock the door and provide passage. It can also report the status of the door (locked or unlocked) at any time.

Date Tehnice

Interfaces: FLN connection to controller: RS485 To readers: One RS485 bus for up to two RS485 readers CerPass protocol) OR two Wiegand/Clock&Data ports

Operating voltage: 24 VDC ±20 %

Power output: Reader: 300 mA / Ancillary: 1 A

Power consumption: 25 W

Outputs: 1 x Lock output relay (30 VDC, 2 A) / 1 x Auxiliary relay (30 VDC, 2 A)

Inputs: 1 x REX-button / 1 x Door contact / 3 x Auxiliary / All inputs unsupervised or supervised

Tamper switch: Optional, auxiliary input

Firmware: Flash upgradeable

Indicators: Power, Activity, Communication

Dimensions (W x H x D): 150 x 150 x 76 mm

Housing protection: IP55

Housing: ABS plastic

Weight: 0.55 kg

Approval: CE


Model: ADD5160 - Dual reader interface module in weatherproof housing
modul usa siemens sipass integrated

Data sheet
descarca .pdf

• The ADD5160 provides an interface between a card reader and the advanced central controller (AC5102 or AC5200) for up to two card readers. When a cardholder presents an access card at an entry or exit reader the ADD5160 reader interface interprets the encoded information and sends this data to the controller. The controller then checks the validity of the cardholder, and if the appropriate permissions have been assigned, the controller sends a message back to the reader interface allowing it to unlock the door and provide passage. It can also report the status of the door (locked or unlocked) at any time.

Date Tehnice

Interfaces: FLN connection to controller: RS485 To readers: One RS485 bus for up to two RS485 readers CerPass protocol) OR two Wiegand/Clock&Data ports

Operating voltage: 24 VDC ±20 %

Power output: Reader: 300 mA / Ancillary: 1 A

Power consumption: 25 W

Outputs: 1 x Lock output relay (30 VDC, 2 A) / 1 x Auxiliary relay (30 VDC, 2 A)

Inputs: 1 x REX-button / 1 x Door contact / 3 x Auxiliary / All inputs unsupervised or supervised

Tamper switch: Optional, auxiliary input

Firmware: Flash upgradeable

Indicators: Power, Activity, Communication

Dimensions (W x H x D): 180 x 180 x 60 mm

Housing protection: IP66

Housing: ABS plastic

Weight: 0.5 kg

Approval: CE


Model: ADD5190 - Dual reader interface module in cabinet
modul usa siemens sipass integrated

• The ADD5190 provides an interface between a card reader and the central controller (AC5200) for up to two card readers. When a cardholder presents the access card at an entry or exit reader the ADD5190 reader interface interprets the encoded information and sends this data to the central controller. The controller then checks the validity of the cardholder, and if the appropriate permissions have been assigned, the controller sends a message back to the reader interface allowing it to unlock the door and provide passage. It can also report the status of the door being locked or unlocked at any time.

Date Tehnice

Interfaces: FLN connection to controller: RS485 To readers: One RS485 bus for up to two RS485 readers CerPass protocol) OR two Wiegand/Clock&Data ports

Operating voltage: 24 VDC ±20 %

Power output: Reader: 300 mA / Ancillary: 1 A

Power consumption: 25 W

Outputs: 1 x Lock output relay (30 VDC, 2 A) / 1 x Auxiliary relay (30 VDC, 2 A)

Inputs: 1 x REX-button / 1 x Door contact / 3 x Auxiliary / All inputs unsupervised or supervised

Tamper switch: Optional, auxiliary input

Firmware: Flash upgradeable

Indicators: Power, Activity, Communication

Dimensions (W x H x D): 200 x 300 x 95 mm

Housing protection: IP0

Housing: Steel

Weight: 2.8 kg

Approval: CE


Model: ADE5300 - Eight-reader interface, including base plate
modul usa siemens sipass integrated

• The ADE5300 provides a local interface between the advanced central controller (AC5100, AC5102 or AC5200) and up to 8 card readers. From the ADE5300, the information held within the access cards is transmitted to the controller. Each time an access attempt is made the controller verifies the data on the ID card and will then either allow or deny access. The ADE5300 can be configured to control up to 8 doors separately or up to 4 doors that include both entry and exit readers. All variations are possible; for example, you can have six single-reader doors and 1 dual-reader door connected to one ADE5300.

Date Tehnice

Interfaces: FLN connection to controller: RS485 To readers: Support for eight readers via RS485 or Wiegand

Operating voltage: 12 to 15 VDC ±10 % 24 VDC -15 to +10 %

Power output: Reader: 8 x 400 mA, 12 VDC / Ancillary: 1 x 1.5 A, 12 VDC

Power consumption: Max. 2 A at 12 V, max. 1.5 A at 24 V

Outputs: 8 x Lock output relay (30 VDC, 2 A) 8 x Open-collector output (100 mA, 9.7-12 VDC) 2 x Fire override relay (30 VDC, 2 A)

Inputs: 8 x Door contact 8 x Request-to-exit 16 x Auxiliary All inputs unsupervised or supervised 2 x Fire override (normal or enhanced mode)

Tamper switch: Optional, auxiliary input

Firmware: Flash upgradeable

Indicators: Power, Activity, FLN Communication, Reader bus communication, Input/output, Fire override

Dimensions (W x H x D): 250 x 287 x 50 mm

Weight: 1.65 kg

Approval: CE, UL294, C-Tick


Model: AFI5100 - Input point module including base plate
modul usa siemens sipass integrated

• The AFI5100 is a programmable input controller used as part of a SiPass integrated system. It provides a local interface between the advanced central controller (AC5100, AC5102 or AC5200) and the devices used to monitor a facility, such as infrared detectors. When an input device that is connected to an AFI5100 changes status, the AFI5100 registers the status change and forwards this data to the controller. After checking the validity of the data, the controller sends the message to the SiPass integrated server, so the alarm-handling mechanism can respond appropriately.

Date Tehnice

Interfaces: To controller: RS485

Operating voltage: 12 to 24 VAC ±20 %

Power consumption: 50 W

Inputs: 32 x internally supplied (supervised or unsupervised) 1 x Tamper (internally supplied) 1 x Fire override (potential-free or internally supplied)

Outputs: 4 x Auxiliary relays (30 VDC, 2 A) 1 x Alarm output (open-collector 12VDC, 200 mA) 1 x Fire override relay (30 VDC, 2 A)

Tamper switch: Optional, auxiliary input

Firmware: Flash upgradeable

Indicators: Power, Activity, FLN Communication, Reader bus communication, Input/output, Fire override

Operating temperature: 0 to +50 °C

Dimensions (W x H x D): 250 x 287 x 30 mm

Weight: 1.35 kg

Approval: CE, UL294, C-Tick


Model: AFO5100 - Output point module (16/16) including base plate
modul usa siemens sipass integrated

Data sheet
descarca .pdf

• The AFO5100 is an advanced, multi-purpose module that provides an interface between powered field-level input contact devices (such as elevator buttons) and output devices (such as override mechanisms) to the advanced central controller (AC5100, AC5102 or AC5200). It is designed for use in elevators that are integrated within an access control environment. A single AFO5100 can provide access control for up to 16 floors and multiple AFO5100 modules can be combined in an elevator system to provide access control for all floors. The fire override mechanism allows floors to be made automatically accessible during an emergency situation, a critical feature for sites where legislation requires strict emergency responses.

Date Tehnice

Interfaces: To controller: RS485

Operating voltage: 12 to 24 VAC ±20 %

Power consumption: 50 W

Inputs: 16 x Isolated (unsupervised external voltage required) 1 x Tamper (internally supplied) 2 x Fire override (potential-free or internally supplied)

Outputs: 16 x Relays (30 VDC, 2 A) 1 x Tamper (open-collector 12 VDC, 100 mA) 2 x Fire override relays (30 VDC, 2 A)

Firmware: Flash upgradeable

Indicators: Power, Activity, FLN Communication, Reader bus communication, Input/output, Fire override

Operating temperature: 0 to +50 °C

Dimensions (W x H x D): 216 x 267 x 30 mm

Weight: 1.3 kg

Approval: CE, UL294, C-Tick


Model: AFO5200 - Output point module (8/8) including base plate
modul usa siemens sipass integrated

Data sheet
descarca .pdf

• The AFO5200 is an advanced, multi-purpose module that provides an interface between field-level input devices (such as passive infrared detectors) and output devices (such as locking devices) to the advanced central controller (AC5100, AC5102 or AC5200).

Date Tehnice

Interfaces: To controller: RS485

Operating voltage: 12/24 VDC (-15 to +10%)

Power consumption: Max. 2 A at 12 V, max. 1.5 A at 24 V

Inputs: 8 x Isolated (internally supplied, unsupervised or supervised) 1 x Local input 1 x Fire override (potential-free or internally supplied)

Outputs: 8 x Relays (30 VDC, 2 A) 1 x Local output (open-collector 9.7-12 VDC, 100 mA) 1 x Fire override relays (30 VDC, 2 A)

Firmware: Flash upgradeable

Indicators: Power, Activity, Communication Inputs, Output Peripheral supplies Fire override

Operating temperature: 0 to +50 °C (32 to 122 °F)

Dimensions (W x H x D): 250 x 210 x 40 mm

Weight: 1 kg

Approval: CE, UL294, C-Tick


Model: ATI5100 - Intrusion arming terminal
modul usa siemens sipass integrated

Data sheet
descarca .pdf

Data sheet
descarca .pdf

• ATI5100 is a field terminal designed for use with SiPass integrated. It acts as a local interface between an advanced central controller (AC5100, AC5102 or AC5200) and authorised cardholders, enabling them to carry out tasks such as arming and disarming intrusion alarm areas.

Date Tehnice

Interfaces: To controller: RS485

Operating voltage: 9 to 30 VDC

Current consumption: Min. by 12 V: 35 mA / Max. by 12 V: 82 mA

Tamper switch: Yes

Firmware: Flash upgradeable

Display: LC: 128 x 64 dots Four lines with 16 characters per line

Buzzer: Integrated Sound level: Different settings for alarms and key press

Operating temperature: 0 to +50 °C

Relative humidity: 93 % (no dew)

Housing: Polycarbonate

Housing protection: IP30

Colour: RAL 9003

Dimensions (W x H x D): 112 x 185 x 28 mm

Weight: 0.38 kg

Approval: CE, C-Tick, UL294 (pending)


Sisteme de Alarma la Efractie

Sisteme Avertizare la Efractie

Sisteme Avertizare la Efractie Complete si Eficiente pentru orice fel de nevoie de Securitate a Casei sau Afacerii Dvs.

Detalii
Sisteme Supraveghere Video

Sisteme Supraveghere Video

Sisteme Supraveghere Video Profesionale pentru Companii si zone Rezidentiale bazate pe Tehnologie de ultima ora.

Detalii
Sisteme Control Acces

Sisteme Control Acces si Pontaj

Accesul Controlat asigura Restrictionarea unor Utilizatori in anumite Zone in functie de nivelul de Securitate stabilit.

Detalii

sisteme de alarmare si stingere incendii

Sisteme de Alarmare si Stingere Incendii

Sisteme de Alarmare si Stingere Incendiu ofera Posibilitatea de Identificare a Zonei cu probleme inainte de Incendiu.

Detalii